2.3.2 Arm connection cable: connector J2
Warning
Install the arm connection cables in the machine before wiring the connector.
• Connect the individual cable wires to the numbered Phoenix 4153612201 screw terminals, as indicated
on the connector and in the following tables, depending on the type of arm in use.
• Connect the finished cable to the E32A SSR interface.
Figure 2-2. Wiring the 4153612201 PHOENIX flying connector to be inserted in J2.
Connector J2
J2
12
1
PIN N° IN/OUT NAME DESCRIPTION
1 IN Touch Probe - Probe status signals
2 IN Touch Probe + Probe status signals
3 IN Arm status Status signal indicating the arm type in use
4 OUT Led status Dual colour arm LED control
5 OUT GNDM Negative of power supply
6 OUT +12VDC Positive of power supply
7 IN Lever locked Indicates the corrected locked of the removable arm to the fixed base
10 OUT GNDT Connected to PE (protective earth) inside to the E32A
ARM
CABLE
E32A
GREEN/PROX UP
BROWN(+12V) + GREY PINK
BLUE/GNDM (SINK)
GREY/LED STATUS
VIOLET/TOUCH PROBE+
WHITE/TOUCH PROBE-
RED-BLUE/ARM STATUS
YELLOW/PROX DOWN